AAQ Monitoring in Power Plant

Dear IENs Good Morning What would be criteria and Frequency for AAQ Monitoring in Power Plant.As in our EC it has been mentioned the it shall be moniored regularly but regularly means what ,should we follow the NAAQ 2009

E-mail me when people leave their comments –

You need to be a member of Paryavaran.com- Indian Environment Network to add comments!

Join Paryavaran.com- Indian Environment Network

Comments

  • As you earlier stated that, you are having online stack gas and AAQM monitoring system.Will you please share information on online AAQM monitoring system?of which company?

  • Dear Himanshu

    You need to installed three AAQM Monitoring stations as per wind direction one at Upwind and two at downwind direction (on 120 degree angle triangle).

    Frquency as per NAAQS 2009 104 readings at each locations means you have to monitor one location twice a week.

    Again all parameter analysis is very costly so you can monitor SOx, NOx, ammonia, Ozone, PM2.5 PM 10 for 104 reading at one location and once in month or qtrly you can grab the sample for metal, Benzene, bezo pyerene.

    I think this will help you to monitor air quality better.

    You can increase the frequency of sampling if these parameters found to be higher than specified limits and after taking corrective action.

    Hope this data will help you.

    Regards,

    Pravin M Jadhav

  • For the purpose to know the frequency of monitoring follow the gude line in EPA-1986 & try to follow the NAAQ 2009 standard only

     

  • We are already having Continuous online Stack and ambient monitoring system in this case what we are suppose to do

     

     

  • The Env Protection Act / Rules prescribes for all large scale (highly polluting industries) industries shall carried out The AAQ Survey twice ina week and in certain cases contineous monitoring is also suggeted based on the public complaints

  • Absolutely AAQM should follow as per NAAQS 2009 norms 104 nos. in the year and twice in a week.

     

    Regards

     

    Dr Hitesh

  • Follow NAAQS 2009
  • as per the cpcb guidlines
  • Yes, that should be the case.

     

    Warm regards

     

    Sudipto

  • If frequency and duration is not defined in EC , follow Consents and if it is not defined in Consents also. I think u need to follow NAAQS-2009.

     

    Regards

     